Please enter your contact, our managers will contact you as soon as possible

Retail Wholesale OEM


Products / Outdoor Heating / De-Icing Systems

Inside-The-Pipe Heating

Design

Gland assembly photo

Pictures illustrating the section entry into the pipe at various angles

Features

  • Designed for installation inside the pipe to be heated
  • Self-limiting heating cable
  • Heat output is automatically adjusted in response to temperature variation inside the pipe
  • Will not overheat or burn out even in case of overlapping
  • Ready-to-use unit
  • Heat output: 10 W/m
  • Special gland assembly for heating cable entry into the pipe included
  • Improved coupling's sealing
  • Recommended for use in contact with potable water

Description

Froststop Pipe Inside is the heating section based on selflimiting heating cable that maintains the required temperature of the pipeline during the whole cold season thus ensuring its good performance, uninterrupted operation and safe condition.

Froststop Pipe Inside section is primary designed for use in case when you are not able to install the heating cable directly on the pipe surface or the pipe is already buried at a depth above the frostline.

Froststop Pipe Inside section is installed inside the pipe filled with water or other non-agressive substance. The section can be also installed outside the pipeline.

The heating section consists of a segment of self-limiting cable equipped with 3-meter cold lead with electric plug at one end and with end termination coupling at the other end. For the section entry into the pipe gland assembly is included in the kit.

The factory made connection and end termination couplings are reliable and tightly sealed.

Electric power is applied from one end of the section. At the far end of the heating segment the end termination coupling is installed that is located inside the pipe and ensures ingress protection rating IP68. For the section entry into the pipe a gland assembly is used consisting of two bushings, two washers and rubber sealing ring.

Application

Application Installation
Open Area Concrete (Sand embedding)
Roof Under Hot Asphalt (short time)
Gutter & Drain pipe Open (UV resistant)
Freeze Protection    

Ordering information

Technical data

Rated voltage 230 VAC, 50 Hz
Linear output (+10 °C) not less than 10 W/m
Maximum operation temperature  
 switched on +65 °C
 switched off +85 °C
Minimum storage temperature –30 °C
Minimum installation temperature –15 °C
Minimum bending radius at installation 35 mm
Cold lead length 3 m
Schuko plug type CEE 7/4
IP protection level IP67
Heating cable outer jacket material Fluoropolymer
Gland assembly thread size 1", ¾"
Maximum permissible pressure 9 atm

Product references

Type Length, m Power, W
Froststop Pipe Inside-2 2 20
Froststop Pipe Inside-4 4 40
Froststop Pipe Inside-6 6 60
Froststop Pipe Inside-8 8 80
Froststop Pipe Inside-10 10 100
Froststop Pipe Inside-12 12 120
Froststop Pipe Inside-16 16 160
Froststop Pipe Inside-20 20 200