Power leads and instrumentation, control cables

Installation wires

Heating section elements designed for heating cable electrical connection

Features

The installation wires are elements of a heating section (complementary to the heating cable, end termination and connection couplings). The wires are designed for connection of the heating cable to power source. Depending on the type of the heating cable (heating section type), one or another installation wire is used. The length of installation wires should not exceed 50 m,but it is allowed to increase their length up to 100 m if required, but in this case conductors of enlarged cross-section must be used (1,5 mm 2– for wires up to 50 m long, 2,5 mm 2 – for wires up to 100 m long).

Installation wires with heating sections/cables correspondence table

Low-temperature wires

Installation wire reference type Outside dimensions Insulation / outer jacket material Heating section type
BU 2×1,50 Installation wire 4,3×7,1 mm Block copolymer / Polyethylene TSOE sections
NUD 3×1,50 Installation wire 8 mm PVC-plastic / Thermoplastic elastomer MHT sections, SSBE sections (based on Freezstop heating cable)
NUD 3×2,50 Installation wire 9,1 mm
NUD 4×1,5 Installation wire 8,6 mm PVC-plastic / Thermoplastic elastomer HCKT sections
NUD 2×1,50 Installation wire 4,3×7,1 mm PVC-plastic / Polyethylene HCKT sections (420 m long)

Medium-temperature wires

Installation wire reference type Outside dimensions Insulation / outer jacket material Heating section type
КР 2×0,75 Installation wire 7 mm Silicone rubber TMOE sections (based on SNKEO cable)
КР 3×1,50 Installation wire 8,4 mm SSBE sections (based on Freezstop S25K, S30 cables)

CONTROL CABLES (command and data cables)

Heating system elements designed for transfer of low-voltage information signals from sensors to temperature controllers

Features

The control cables are designed for transfer of low-voltage information signals from sensors of temperature, precipitation and water to analog or digital temperature controllers

Reference type (Ordering information) Scope of application
Temperature controllers
Sensor Control cable lengths restrictions, m
1 Cable FTP Cat 5-е 4×2×0,5 24
AWG «Outdoor»
КММ3×0,12
РТ-200, РТ-220, РТМ-2000 TST01 Temperature
sensor
2 Cupper single-wire core 5×1.5
within PVC insulation, PVC outer jacket
rated voltage with frequency of up to 100 Hz, U=0.66 kV;
Uconst = 1 kV; core insulation resistance 10 MOhm
ultimate operating temperature from -50 °С upto +50 °С
flame-proof
РТ-200, РТ-220, РТМ-2000 TSW01 Water sensor
TSP01 Precipitation sensor
TSP02 Precipitation sensor
3 Cupper single-wire core 4×1.5 within PVC insulation, PVC outer jacket
rated voltage with frequency of up to 100 Hz, U=0.66 kV;
Uconst = 1 kV; core insulation resistance 10 MOhm
ultimate operating temperature from -50 °С upto +50 °С flame-proof
РТ-400 TC-1388 Temperature
transducer
4 Cupper single-wire core 2×1.5 within PVC insulation, PVC outer jacket
rated voltage with frequency of up to 50 Hz, U=0.66 kV and 1 kV ultimate operating temperature from -50 °С upto +50 °С or
Cupper multi-wire core 2×1.5 within PVC insulation, PVC outer jacket
rated voltage with frequency of up to 50 Hz, U=0.38 kV ultimate operating temperature from -25 °С upto +40 °С
РТ-330, ТР 140 TST05 Temperature sensor